Featured Brands
Model#: 381
Stock#: FLK-381
UPC/GTIN/EIN: 095969537483
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex
$895.99 Sale price: $895.99
- Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy
- A removable magnetic display can be mounted where it is easily seen
- iFlex Flexible Current Probe expands the measurement range to 2500 A AC
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex
Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display, and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.
The iFlex Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward-sized conductors, and disorganized wires.
What's in the Box:
- 381 Remote Display Clamp Meter
- (1 pair) TL75 test leads
- (1 pair) AC175 alligator clips
- 18-inch iFlex flexible current probe
- Soft carrying case
Features:
- Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy
- A removable magnetic display can be mounted where it is easily seen
- iFlex Flexible Current Probe expands the measurement range to 2500 A AC
- CAT IV 600 V, CAT III 1000 V
- Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Three-year warranty
Specifications:
- Electrical Specifications:
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy:
- 2% ± 5 digits (10-100 Hz)
- 5% ± 5 digits (100-500 Hz)
- Crest Factor (50/60 Hz):
- 3 @ 500 A
- 2.5 @ 600 A
- 1.42 @ 1000 A
- Add 2% for C.F. > 2
- AC Current via Flexible Current Probe:
- Range: 999.9 A / 2500 A (45 Hz – 500 Hz)
- Resolution: 0.1 A / 1 A
- Accuracy: 3% ± 5 digits
- Crest Factor (50/60 Hz):
- 3.0 at 1100 A
- 2.5 at 1400 A
- 1.42 at 2500 A
- Add 2% for C.F. > 2
- DC Current
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2% ± 5 digits
- AC Voltage
- Range: 600 V /1000 V
- Resolution: 0.1 V / 1 V
- Accuracy: 1.5% ± 5 digits (20 – 500 Hz)
- DC Voltage
- Range: 600.0 V /1000 V
- Resolution: 0.1 V / 1 V
- Accuracy: 1% ± 5 digits
- Frequency – Via Jaw:
- Range: 5.0 – 500.0 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5% ± 5 digits
- Trigger Level:
- 5 – 10 Hz, ≥ 10 A
- 10 – 100 Hz, ≥ 5 A
- 100 – 500 Hz, ≥ 10 A
- Frequency via Flexible Current Probe:
- Range: 5.0 to 500.0 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5% ± 5 digits
- Trigger Level:
- 5 to 20 Hz, ≥ 25 A
- 20 to 100 Hz, ≥ 20 A
- 100 to 500 Hz, ≥ 25 A
- Resistance:
- Range: 600 Ω/6 kΩ/60 kΩ
- Resolution: 0.1 Ω/1 Ω/10 Ω
- Accuracy: 1% ± 5 digits
- Mechanical Specifications:
- Size (L x W x H): 277 x 88 x 43 mm (55 mm for remote unit)
- Weight: 350 g
- Jaw Opening: 34 mm
- Flexible Current Probe Diameter: 7.5 mm
- Flexible Current Probe Cable Length (head to electronics connector): 1.8 m
- Environmental Specifications:
- Operating Temperature: -10°C to +50°C
- Storage Temperature: -40°C to +60°C
- Operating Humidity:
- Non condensing (< 10°C)
- ≤ 90% RH (at 10°C to 30°C)
- ≤ 75% RH (at 30°C to 40°C)
- ≤ 45% RH (at 40°C to 50°C)
- (Without Condensation)
- Operating Altitude: 2,000 meters
- Storage Altitude: 12,000 meters
- EMI, RFI, EMC, RF:
- EN 61326-1:2006, EN 61326-2-2:2006
- ETSI EN 300 328 V1.7.1:2006
- ETSI EN 300 489 V1.8.1:2008
- FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
- FCCID: T68-F381
- RSS-210 IC: 6627A-F381
- Temperature Coefficients: Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
- Wireless Frequency: 2.4 GHz ISM Band 10 meter range
- Safety Compliance:
- ANSI/ISA S82.02.01:2004
- CAN/CSA-C22.2 No. 61010-1-04
- IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
- Double Insulation Clearance: Per IEC 61010-2-032
- Double Insulation Creepage: Per IEC 61010-1
FLK-381
Manufacturer: | Fluke |